MALLINCKRODT MEDICAL INC -- ASCORBIC ACID -- 6810-00F013163
=====================  Product Identification  =====================

Product ID:ASCORBIC ACID
MSDS Date:01/01/1997
FSC:6810
NIIN:00F013163
=== Responsible Party ===
Company Name:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Info Phone Num:314-770-7800/314-895-2000
Emergency Phone Num:314-770-7800
CAGE:FO650
=== Contractor Identification ===
Company Name:MALLINCKRODT DIAGNOSTICS
Address:2703 WAGNER PLACE
Box:City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-344-3800
CAGE:2A916
Company Name:MALLINCKRODT MEDICAL INC
Address:2703 WAGNER PLACE
City:MARYLAND HEIGHTS
State:MO
ZIP:63043-3421
Country:US
Phone:314-770-7800/314-895-2000
CAGE:FO650

=============  Composition/Information on Ingredients  =============

Ingred Name:L-ASCORBIC ACID, ASCORBIC ACID
CAS:50-81-7
RTECS #:CI7650000

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGESTION: LARGE DOSES MAY CAUSE GI
    UPSET. EYES: MAY CAUSE MECHANICAL IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:GI UPSET, IRRITATION.

=======================  First Aid Measures  =======================

First Aid:INGESTION: GIVE WATER TO DRINK. SKIN: WASH W/SOAP & WATER.
    EYES: FLUSH W/RUNNING WATER FOR 15 MINS. OBTAIN MEDICAL ATTENTION
    IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
    SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING & NIOSH APPROVED
    SCBA W/FULL FACEPIECE OPERATED IN THE PRESSURE DEMAND/OTHER
    POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:NON-FIRE/EXPLOSION HAZARD.

==================  Accidental Release Measures  ==================

Spill Release Procedures:COLLECT ALL NON-RADIOACTIVE & DISPOSE OF AS
    NON-HAZARDOUS WASTE. FOR ASCORBIC ACID ADDED TO SODIUM CHROMATE CR
    51 INJECTION: IF ANY LOSS/RELEASE OF RADIOACTIVE MATERIALS OCCUR,
    NOTIFY MALLINCKRODT. AL L CLEANUP OPERATIONS SHOULD BE PERFORMED BY
    SOPS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AT 59-86F. PRESSURE MAY DEVELOP
    W/IN AMPULE LONG STORAGE. HANDLING TIME SHOULD BE KEPT TO A MINIMUM
    & SHIELDING SHOULD BE USED.
Other Precautions:PRECAUTIONS SHOULD BE TAKEN TO WRAP THE CONTAINER IN
    A PROTECTIVE COVERING WHILE OPENING. HANDLING DEVICES SUCH AS
    SYRINGE SHIELDS & TONGS SHOULD BE USED. STORAGE & DISPOSAL SHOULD
    BE CONTROLLED IAW/A PPROPRIATE REGULATIONS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
    USAGE.
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:PROTECTIVE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:CLEAN BODY COVERING CLOTHING.
Work Hygienic Practices:REMOVE ANY CONTAMINATION FROM THE SKIN,
    EYES/CLOTHING.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:377.6F
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS LIQUID IN 2 ML AMPULES; ODORLESS

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:ASCORBIC ACID EMITS ACRID SMOKE &
    IRRITATING FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RADIOACTIVE WASTE MUST BE HANDLED IAW/FEDERAL,
    STATE & LOCAL REGULATIONS. IF MEDICAL WASTE IS INVOLVED, SUCH AS
    BLOOD, BLOOD PRODUCTS/SHARPS, THE WASTE MUST BE HANDLED AS A
    BIOHAZARD & DISPOSED OF ACC ORDINGLY. ASCORBIC ACID IS
    NON-HAZARDOUS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.