AIR PRODUCTS AND CHEMICALS INC -- HYDROGEN, COMPRESSED -- -
===================== Product Identification =====================
Product ID:HYDROGEN, COMPRESSED
MSDS Date:06/01/1994
FSC:NIIN:Submitter:D DG
Status Code:A
=== Responsible Party ===
Company Name:AIR PRODUCTS AND CHEMICALS INC
Address:7201 HAMILTON BLVD
City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Info Phone Num:800-345-3148/610-481-4911
Emergency Phone Num:1-800-752-1597
Resp. Party Other MSDS Num.:1009
Preparer's Name:NOT PROVIDED
CAGE:00742
=== Contractor Identification ===
Company Name:AIR PRODUCTS AND CHEMICALS INC
Address:7201 HAMILTON BLVD
Box:City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Phone:800-345-3148/ 800-752-1597
Contract Num:SP0450-01-M-ZE95
CAGE:00742
============= Composition/Information on Ingredients =============
Ingred Name:HYDROGEN
CAS:1333-74-0
RTECS #:MW8900000
> Wt:99.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NOT RELEVANT
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: ASPHYXIANT. IT SHOULD BE
NOTED THAT BEFORE SUFFOCATION COULD OCCUR, THE LOWER FLAMMABILITY
LIMIT OF HYDROGEN IN AIR WOULD BE EXCEEDED POSSIBLY CAUSING BOTH AN
OXYGEN-DEFICIENT AND EXPLOSIV E ATMOSPHERE. EXPOSURE TO MODERATE
CONCENTRATIONS MAY CAUSE DIZZINESS, HEADACHE, NAUSEA AND
UNCONSCIOUSNESS. EXPOSURE TO ATMOSPHERES CONTAINING 8-10% OR LESS
OXYGEN WILL QUICKLY BRING ABOUT UNCONSCIOU SNESS WITHOUT WARNING
LEAVING INDIVIDUALS UNABLE TO PROTECT THEMSELVES. LACK OF
SUFFICIENT OXYGEN MAY CAUSE SERIOUS INJURY OR DEATH. EYE CONTACT:
NONE. SKIN CONTACT: NONE. CHRONIC EFFECTS: NONE. OTHER EFFECTS OF
OVEREXPOSURE: NONE.
Explanation of Carcinogenicity:HYDROGEN IS NOT LISTED BY NTP, OSHA OR
IARC.
Effects of Overexposure:EXPOSURE TO AN OXYGEN-DEFICIENT ATMOSPHERE
(<19.5%) MAY CAUSE DIZZINESS, DROWSINESS, NAUSEA, VOMITING, EXCESS
SALIVATION, DIMINISHED MENTAL ALERTNESS, LOSS OF CONSCIOUSNESS, AND
DEATH. TARGET ORGANS: NONE. EFFECT: ASPHYXIATION (SUFFOCATION)
Medical Cond Aggravated by Exposure:NONE.
======================= First Aid Measures =======================
First Aid:INHALATION: PERSONS SUFFERING FROM LACK OF OXYGEN SHOULD BE
REMOVED TO FRESH AIR. IF VICTIM IS NOT BREATHING, ADMINISTER
ARTIFICAL RESPIRATION. IF BREATHING IS DIFFICULT, ADMINISTER
OXYGEN. OBTAIN PRO MPT MEDICAL ATTENTION. SKIN CONTACT: NONE. EYE
CONTACT: NONE. INGESTION: NONE. NOTES TO PHYSICIAN: NONE.
===================== Fire Fighting Measures =====================
Flash Point:FLAMMABLE GAS
Autoignition Temp:=565.6C, 1050.F
Lower Limits:4%
Upper Limits:74%
Extinguishing Media:CO2, DRY CHEMICAL, WATER SPRAY OR FOG FOR
SURROUNDING AREA. DO NOT EXTINGUISH UNTIL HYDROGEN SOURCE IS SHUT
OFF.
Fire Fighting Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA.
IMMEDIATELY COOL CONTAINER WITH WATER SPRAY FROM MAXIMUM DISTANCE,
TAKING CARE NOT TO EXTINGUISH FLAMES. IF FLAMES ARE ACCIDENTALLY
EXTINGUISHED, EXPLOSIVE RE- IGNITION MAY OCCUR. STOP FLOW OF GAS IF
WITHOUT RISK WHILE CONTINUING COOLING WATER SPRAY.
Unusual Fire/Explosion Hazard:BURNS WITH A PALE BLUE, NEARLY INVISIBLE
FLAME. HYDROGEN IS EASILY IGNITED WITH LOW-IGNITION ENERGY,
INCLUDING STATIC ELECTRICITY. HYDROGEN IS LIGHTER THAN AIR AND CAN
ACCUMULATE IN THE UPPER SECTIONS OF ENCLOSED SPACES. PRESSURE IN A
CONTAINER CAN BUILD UP AND IT MAY RUPTURE IF PRESSURE RELIEF
DEVICES SHOULD FAIL.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE IMMEDIATE AREA. ELIMINATE ANY
POSSIBLE SOURCES OF IGNITION, AND PROVIDE MAXIMUM EXPLOSION-PROOF
VENTILATION. SHUT OFF SOURCE OF HYDROGEN, IF POSSIBLE. IF LEAKING
FROM CYLINDER, OR VALVE, CALL THE AIR PRODUCTS' EMERGENCY PHONE
NUMBER. THE PRESENCE OF A HYDROGEN FLAME CAN BE DETECTED BY
APPROACHING CAUTIOUSLY WITH AN OUTSTRETCHED STRAW BROOM TO MAKE THE
FLAME VISIBLE.
Neutralizing Agent:NOT RELEVANT
====================== Handling and Storage ======================
Handling and Storage Precautions:CYLINDER STORAGE LOCATIONS SHOULD BE
WELL-PROTECTED, WELL-VENTILATED, DRY AND SEPARATED FROM COMBUSTIBLE
MATERIALS. CYLINDERS SHOULD NEVER REACH A TEMPERATURE ABOVE
125F/52C. SEPARATE FROM OXYDIZERS BY A MINIMUM DISTANCE OF 20 FT.
STORE CYLINDERS UPRIGHT, SECURED WITH VALVE PROTECTION CAP IN
PLACE.
Other Precautions:DO NOT OPEN HYDROGEN CYLINDER VALVE BEFORE CONNECTING
IT, SINCE SELF-IGNITION MAY OCCUR. HYDROGEN IS LIGHTEST GAS KNOWN
AND MAY COLLECT IN TOP OF BUILDINGS WITHOUT PROPER VENTILATION. IT
MAY LEAK OUT OF A SYSTEM WHICH IS GAS-TIGHT FOR AIR/OTHER GASES.
LEAK CHECK SYSTEM WITH LEAK DETECTION SOLUTION, NEVER WITH FLAME.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:GENERAL USE: NONE. EMERGENCY USE: AIR SUPPLIED
RESPIRATORS ARE REQUIRED IN OXYGEN-DEFICIENT ATMOSPHERES. BEFORE
ENTERING AREA YOU MUST CHECK FOR FLAMMABLE OR OXYGEN-DEFICIENT
ATMOSPHERES.
Ventilation:PROVIDE NATURAL OR EXPLOSION-PROOF VENTILATION ADEQUATE TO
ENSURE HYDROGEN DOES NOT REACH ITS LOWER EXPLOSIVE LIMIT OF 4%.
Protective Gloves:WORK GLOVES ARE RECOMMENDED WHEN HANDLING CYLINDERS.
Eye Protection:SAFETY GLASSES ARE RECOMMENDED WHEN HANDLING CYLINDERS.
Other Protective Equipment:SAFETY SHOES ARE RECOMMENDED WHEN HANDLING
CYLINDERS.
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
ABBREVIATION: N/A = NOT APPLICABLE. N/AV = NOT AVAILABLE. N/K =
UNKNOWN. N/P = NOT PROVIDED. N/R = NOT RELEVANT. N/D = NOT
DETERMINED. N/E = NOT ESTABLISHED. CNS = CENTRAL NERVOUS SYSTEM. GI
= GASTROI NTESTINAL. SCBA = SELF CONTAINED BREATHING APPARATUS.
================== Physical/Chemical Properties ==================
HCC:G2
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=-252.6C, -423.F
Melt/Freeze Pt:=-259.C, -434.5F
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Density:0.06960
Spec Gravity:0.00521 LB/FT3
Solubility in Water:(VOL/VOL@60F(15.6C):0.019
Appearance and Odor:COLORLESS GAS AT NORMAL TEMPEATURE AND PRESSURE.
ODOR: ODORLESS
Percent Volatiles by Volume:>99
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS. SOME STEELS ARE SUSCEPTIBLE TO HYDROGEN EMBRITTLEMENT
AT HIGH PRESSURES AND TEMPERATURES.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE
=================== Toxicological Information ===================
Toxicological Information:HYDROGEN IS A SIMPLE ASPHYXIANT.
===================== Ecological Information =====================
Ecological:NO ADVERSE EFFECTS ARE EXPECTED. HYDROGEN DOES NOT CONTAIN
ANY CLASS 1 OR CLASS II OZONE DEPLETING CHEMICALS (40 CFR PART 82).
HYDROGEN IS NOT LISTED AS A MARINE POLLUTANT BY DOT (49 CFR PART
171).
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF RESIDUAL OR UNUSED
PRODUCT IN THE CYLINDER. RETURN TO SUPPLIER FOR SAFE DISPOSAL.
RESIDUAL PRODUCT WITHIN PROCESS SYSTEM MAY BE VENTED AT A
CONTROLLED RATE, TO THE ATMOSPH ERE THROUGH A VENT STACK THAT
DISCHARGES TO AN ELEVATED POINT. THIS STACK SHOULD BE IN AN
ISOLATED A REA AWAY FROM IGNITION SOURCES.
=================== MSDS Transport Information ===================
Transport Information:DOT/IMO SHIPPING NAME: HYDROGEN, COMPRESSED.
HAZARD CLASS: 2.1 (FLAMMABLE GAS). IDENTIFICATION NUMBER: UN 1049.
PRODUCT RQ: NONE. SHIPPING LABEL: FLAMMABLE GAS. PLACARD (WHEN
REQUIRED): FLAMMABLE GAS. CYLINDER SHOULD BE TRANSPORTED IN A
SECURE POSITION, IN A SECURE UPRIGHT POSITION IN A WELL-VENTILATED
TRUCK. NEVER TRANSPORT IN PASSENGER COMPARTMENT OF A VEHICLE.
SHIPMENT OF COMPRESSED GAS CYLINDE RS WHICH HAVE NOT BEEN FILLED
WITH THE OWNER'S CONSENT IS A VIOLATION OF FEDERAL LAW (49 CFR PART
173.301 (B))
===================== Regulatory Information =====================
SARA Title III Information:SARA: SUPERFUND AMENDMENTS AND
REAUTHORIZATION ACT: SECTION 302/304: REQUIRES EMERGENCY PLANNING
ON THRESHOLD PLANNING QUANTITIES (TPQ) AND RELEASE REPORTING BASED
ON REPORTABLE QUANTITIES (RQ) OF EPA 'S EXTREMELY HAZARDOUS
SUBSTANCES (40 CFR PART 355). EXTREMELY HAZARDOUS SUBSTANCES: NONE.
THRESHOLD PLANNING QUANTITIES (TPQ): NONE. SECTION 311/312: REQUIRE
SUBMISSION OF MATERIAL SAFETY DATA SHEETS (MSDSS) AND CHEMICAL
INVENTORY REPORTING IDENTIFICATION OF EPA DEFINED HAZARD CLASSES
(40 CFR PART 370). THEHAZARD CLASSES FOR THIS PRODUCT ARE:
PRESSURE, FIRE. SECTION 313: NOT REQUIRED REPORTING.
Federal Regulatory Information:TSCA: TOXIC SUBSTANCE CONTROL ACT:
HYDROGEN IS LISTED ON THE TSCA INVENTORY. CERCLA: COMPREHENSIVE
ENVIRONMENTAL RESPONSE, COMPENSATION AND LIABILITY ACT OF 1980 (40
CFR PART 117 AND 302): REPORTABLE QUANTITY (RQ): NONE. 40 CFR PART
68: RISK MANAGEMENT FOR CHEMICAL ACCIDENTAL RELEASE: HYDROGEN IS
NOT LISTED AS A REGULATED SUBSTANCE. HOWEVER, ANY PROCESS THAT
INVOLVES A FLAMMABLE GAS ON SITE IN ONE LOCATION, IN QUANTITIES OF
10,000 POUDS (4,553 KG) OR GREATER, IS COVERED UNDER THIS
REGULATION. OS HA 29 CFR 1910.119: NOT LISTED IN APPENDIX A BUT >=
10,000 LBS IS COVERED UNDER THIS REGULATION.
State Regulatory Information:NOT PROVIDED
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.